Hey everyone, let’s cut to the chase—if you’ve ever stared at a permanent magnet synchronous motor (PMSM) control panel like it’s a foreign language, you’re not alone. I’m the team lead over at our PMSM supply shop, and over the past 7 years, I’ve walked new maintenance techs, small factory owners, and even hobbyists through starting these things a hundred times. Yeah, they’re way more efficient than their induction cousins, but skip a step here or misread a sensor there, and you’ll be staring at a dead motor (or worse, a panicked team) before you can say “rare-earth magnet.” This post isn’t some stuffy engineering manual—it’s the real, no-BS playbook I’ve used day in and day out, plus some pro tips I only pass on to people who actually need to get their lines running. Permanent Magnet Synchronous Motor

First off, let’s nail down what a PMSM actually relies on, because starting it is 90% setting up for success before you even hit that start button. Unlike induction motors, which “induce” their own rotor magnetic field, PMSMs have permanent magnets glued or secured right in the rotor. That means they’re way more precise with speed and torque—perfect for conveyor systems, electric forklifts, or even those big HVAC blowers you see in commercial buildings. But that precision only works if you get two things right first: rotor position feedback and the inverter’s output. Mess up either, and you’re looking at “cogging” (that jerky, not-quite-moving spin) or even backfeeding power that fries your inverter.
Before we get to the step-by-step, let’s do a quick pre-start check that takes 5 minutes tops—don’t skip this. I’ve had a client call me at 7 a.m. last month, screaming their motor wouldn’t start, only to find a tech had left the protective cover off the terminal box, and a stray wrench nicked a power cable overnight. Here’s my go-to checklist: First, grab your multimeter (you don’t need a fancy lab one—just a basic digital model works) and check the DC bus voltage. That’s the big cap bank sitting in the inverter cabinet. If it’s way lower than rated (like, our 48V PMSMs need 52-56V DC to start), you’ve got a loose connection or a dead capacitor charging. Next, check the phase wires between the inverter and motor—should read roughly the same resistance on all three (like, within 10% of each other). If one’s way higher, you’ve got a broken wire or a corroded terminal. Last, do a quick visual of the motor itself: spin the rotor by hand (make sure power is OFF, duh) — it should spin smooth, no grinding or scraping. If it catches, you’ve got a bearing issue, not a starting problem, and we can fix that before you waste 20 minutes messing with controls.
Okay, the main event—starting the PMSM. I split this into two modes because, trust me, not all starts are the same. If you’re doing a regular, low-load start (like a conveyor that’s empty), go with sensor-based vector control—it’s what our factory sets as default for 90% of orders, and it’s the most reliable for day-to-day use. If you’re cranking a heavy load (like a fully loaded forklift or a packaging line with 10 boxes stacked), use sensorless vector control with a low-speed pre-excitation step, but hold up—more on that later. Let’s start with the regular sensor-based start, since that’s what most folks will deal with.
First, make sure all the auxiliary power is on. The inverter, the PLC, any encoder cables (that’s the thing that tells the motor where the rotor is—super important), all should be powered up and communicating. If you get an error code here (most common ones are “encoder comm loss” or “bus undervoltage”), just go back to your pre-start check—9 times out of 10, it’s a loose encoder connector. Next, zero the reference position. This is the big one I see new techs mess up all the time. The encoder doesn’t know where the rotor’s North pole is unless you tell it. Most modern inverters (ours included) have an auto-alignment routine, so you don’t have to do it manually. Here’s how we run it: Hold the start button for 3 seconds, or navigate the inverter’s little touchscreen (or keypad, if it’s the older model) to find the “Rotor Alignment” function, and hit enter. The motor will make a small, quiet click and twist about 10 degrees—don’t panic, that’s just it locking onto the magnet. That’s normal. If it beeps and gives an error here, turn off the inverter, spin the rotor by hand a quarter turn, and try again. I once had a client who skipped this step and tried to start their 10HP PMSM, and it locked up so hard she had to call a mechanic to break it free. Oops.
Now, set your speed reference. Most systems have two ways: analog (a 0-10V signal, usually from a PLC or potentiometer) or digital (an HMI input or a predefined setpoint). Don’t jump straight to full speed—start at 25-30% of your rated speed first. Why? This lets you check for cogging. If the motor jerks and doesn’t spin, shut it off immediately. That’s either a bad alignment or a load that’s too high for the start mode. Once it spins smooth at low speed, you can ramp up to your target speed at about 10% per second. No fast ramps—PMSMs hate that, and it’s a quick way to wear down the bearings or trip overcurrent protection. Once you hit your set speed, hold it for 30 seconds. If there are no error codes, you’re good to go. Most of our clients leave this part alone because we pre-program the inverter, but it’s good to know if you ever need to adjust it.
Now, that heavy-load start I mentioned earlier—this is where sensorless mode comes in. Sensorless is great because you don’t need an encoder, so it’s cheaper, but it doesn’t have that exact rotor position feedback. For loads over 70% of the motor’s torque rating, sensorless can fail if you skip the pre-excitation step. Here’s how we do that: First, set the speed reference to 5-10% (way lower than the regular start). Then, hold the start button for 5 seconds instead of 3. The inverter will send a small DC current to the stator for a second, “waking up” the permanent magnets so it can get a rough position. Then it’ll start ramping up slow. This avoids that dead spot where the rotor just sits there because it’s aligned wrong. I used to skip this when I was new, and I ruined two PMSMs before my boss sat me down and told me I was being an idiot. Don’t be that guy.
Wait, let’s talk about common mistakes that’ll get you in trouble. First, overloading at start. A lot of folks think, “My motor is 20HP, so it can start my 20HP load” but PMSMs only have so much starting torque. If you’re starting a full load, even a big PMSM needs that pre-excitation step. Second, ignoring error codes. I know, it’s tempting to just hit reset and keep going, but that error code is telling you something. Last month, a local bakery’s motor kept throwing an overcurrent error. They hit reset three times, and eventually the inverter tripped permanent. When I checked, the conveyor belt was jammed with dough, so the motor was pulling way more current than it should. If they’d checked the error code first, they would’ve fixed the jam in 2 minutes instead of ordering a new inverter.
Also, a quick note on safety—always, always make sure the motor is isolated from the load before doing a test start. If you start the motor with the conveyor belt connected and something’s wrong, you’ve got a runaway belt, which is a hazard. Last thing: after starting, listen to it. A healthy PMSM should make a quiet, steady hum—no grinding, no high-pitched whine, no sudden changes in sound. If it does, shut it down and check that pre-start checklist again.

At the end of the day, starting a PMSM isn’t rocket science, but it’s not just plug and play either. It’s about nailing that pre-start check, getting the rotor aligned right, and picking the right start mode for your load. If you’re messing with these regularly, get to know your motor’s specs—our team can hook you up with a free spec sheet if you need it, no pressure. If you’ve got a PMSM that won’t start, or you’re looking to upgrade to a more efficient unit, hit us up—we don’t do sales fluff, just honest advice and parts that actually work.
Explosion Proof Motor References
- Bose, Bimal K. "Modern Power Electronics and AC Drives." Prentice Hall, 2002.
- Permanent Magnet Synchronous Motor Application and Installation Guide. Magnetek Industrial Automation, 2021.
- "Rotor Position Alignment for Sensor-Based PMSMs." IEEE Transactions on Industrial Electronics, vol. 65, no. 11, 2018, pp. 8501-8510.
Xi’an Simo Motor Co., Ltd.
Xi’an Simo Motor Co., Ltd. is well-known as one of the leading permanent magnet synchronous motor manufacturers and suppliers in China. Please feel free to buy high-grade permanent magnet synchronous motor in stock here and get quotation from our factory. All customized products are with high quality and low price.
Address: No. 159 Mingguang Road Economic and Technological Development Zone, Xi’an, Shaanxi Province, China
E-mail: mkt-sales@simo.com.cn
WebSite: https://www.simomotor.com.cn/